MACROMATIC INDUSTRIAL CONTROLS TR-6022U TIME DELAY RELAY PLUG 24240AC/12-125DC 10A DPDT
Description
Time Delay Relay. Upon application of input voltage, the output is energized and the time delay (t1) begins. At the end of the time delay (t1), the output is de-energized and remains in that condition for the time delay (t2). At the end of this time delay, the output is energized and the sequence repeats until input voltage is removed. Universal input voltage: 24-240V AC and 12-125V DC. Each unit has 16 timing ranges built-in covering 0.05 seconds-100 hours. Selecting a range is easy using a rotary switch (no math is required or DIP switches to set). Multi-function versions. 10A output contacts can handle most pilot duty and fractional HP loads.
Specifications
Brand Name | Macromatic | Item Name | Time Delay Relay |
Voltage Rating | 24 - 240 VAC, 12 - 125 VDC | Contact Rating | 10 A at 240 VAC/30 VDC |
Contact Configuration | DPDT | Terminal Connection | 8-Pin/11-Pin Octal Socket |
Maximum Load Capacity | 3 VA | Series/Model | TR-6 |
Amperage Rating | 10 A | Frequency Rating | 50/60 Hz |
HP Rating | 1/2 hp at 120/240 VAC, 1/3 hp at 120/240 VAC | Operating Cycles | 10000000 Mechanical, 100000 Full Load |
Operate Time | 0.05 sec - 100 hr | Release Time | 0.1 sec (Functions Triggered with Input Voltage), 0.04 sec (Functions Triggered with Control Switch) |
Mounting Type | Plug-In | NEMA Rating | NEMA B300, R300, AC15, DC13 |
Temperature Rating | -28 to 65 °C | Standards | CE Certified, cURus, UL Listed |
UPC | 801262088016 |